INTERSEAL 211 PDF

With the patented dry®, interseal has developed a technically and . 8 x 8 x microns ( mils) dry equivalent to. microns ( mils) wet . Interseal Interthane SYSTEMS. COMPATIBILITY. Sep 22 , , SYNTHETIC ENAMEL PAINT, INTERSEAL HSALUMINIUM PART A EGA/20LT, Sri Lanka, Bangalore, LTR, , 35,,

Author: Faegore Barg
Country: Romania
Language: English (Spanish)
Genre: Video
Published (Last): 25 January 2012
Pages: 43
PDF File Size: 3.91 Mb
ePub File Size: 8.51 Mb
ISBN: 902-5-95007-597-9
Downloads: 11840
Price: Free* [*Free Regsitration Required]
Uploader: Samular

Interseal | Protective – Coatings – AkzoNobel

Mouse over image to zoom. Intercure HS can also be used as a primer for substrates other than blasted steel, e. Press and move to zoom. Prior to paint application, all surfaces should be assessed and treated in accordance with ISO Zinc Phosphate version also available.

Search Import Export Data of India

Intercure HS is not intended for use as a primer for steelwork which may be subjected to continuous immersion conditions. This product is not available in pale and pastel shades due to a tendency to discolour rapidly. Intercure HS is suitable for application to blast cleaned surfaces which were initially to the above standard but have been allowed to deteriorate under good shop conditions for up to days.

Over-application should be avoided as thick films will not be as good a substrate for topcoat adhesion after ageing as those at the specified thickness. Over-application of Intercure HS will extend both the minimum overcoating periods and handling times, and may be detrimental to long term overcoating properties. Low Temperature Curing 24 Hours 1. Thoroughly flush all equipment with International GTA Available in colours as well as aluminium and glass flake versions with passivator, to provide additional anti-corrosive barrier protection.

  GENETICA MODERNA GRIFFITHS PDF

Frequency of cleaning will depend upon amount sprayed, temperature and elapsed intersela, including any delays. Always mix a complete unit in the proportions supplied. GTA Do not thin more than allowed by local environmental legislation Mix ratio: Absolute measured adhesion of topcoats to aged Intercure HS is less than that to fresh material, however, it is adequate for the specified end use.

Interseal dries to form a non-tacky, tough, resilient temporary protective layer. As a primer for steelwork intended for use in a wide range of environmental conditions including offshore, chemical and petrochemical plants, industrial buildings, pulp and paper mills, power plants and ingerseal. However, these phenomena are not detrimental to anti-corrosive performance. A high solids, low VOC, two component, high build, surface tolerant epoxy coating, Interseal HS provides excellent anticorrosive protection in industrial and offshore environments in both atmospheric exposure and immersion service.

A low VOC, two component high build, high solids surface tolerant epoxy maintenance coating. If oxidation has occurred between blasting and application of Intercure HS the surface should be reblasted to the specified visual standard.

INTERCURE HS – PART B – L

A two component, low VOC, high solids, fast curing anticorrosive epoxy primer. However, if necessary, application over prefabrication blast primers can be performed.

A two component, low VOC, high solids epoxy, pigmented with aluminium to provide enhanced corrosion resistance. Dry time 1 Hours 1 26 Inherseal 1 48 Hours 1 8 Hours 1. Product Type Primer Chemistry Epoxy. If the shop primer shows extensive or widely scattered breakdown overall sweep blasting maybe necessary.

Suitable for overcoating within 7 hours in most climatic conditions hence speeding up production and throughput in fabrication shops. VOC values are typical and are provided for guidance purpose only. Consult International Protective Coatings for inerseal details. This product must only be thinned using recommended International GTA thinners. Systems compatibility Intercure HS will normally be applied to suitably prepared steel, e. Warning Intercure HS intersfal preferred for use with systems for chemical environments where zinc based materials can be subject to attack in both acidic and alkaline conditions.

  CRONICAS PARA LER NA ESCOLA CARLOS HEITOR CONY EM PDF

The surface may deteriorate to Sa2 standard but must be free from loose powdery deposits.

INTERCURE 200HS – PART B – 3.79L

Number of Components Multi pack 4 Single Pack 2. Once the unit has been mixed, it must be used within the working pot life specified.

Be the first to write a review for this product! Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed units. Additionally, in common with all epoxies Intercure HS will chalk on exterior exposure.

Excessive over application of material on areas such as poorly prepared welds may result in long term stress cracking and so early failure.

A single component, spray applied, high build, water based coating for direct application over coated substrates and non-ferrous substrates. Product Line Interseal 6. Provides quick cure even at low temperatures often encountered in maintenance painting. Surface defects revealed by the blast cleaning process should be ground, ihterseal, or treated in the appropriate manner.