ASTM F138 PDF

ASTM Fa. Standard Specification for Wrought 18ChromiumNickel Molybdenum Stainless Steel Bar and Wire for Surgical Implants. Find the most up-to-date version of ASTM F at Engineering Mechanical values listed above are typical for uniaxial tension. Upon request, we can also deliver this material with other properties. L (ASTM F), Ti.

Author: Kigazahn Murn
Country: Croatia
Language: English (Spanish)
Genre: Career
Published (Last): 27 June 2007
Pages: 239
PDF File Size: 16.2 Mb
ePub File Size: 5.67 Mb
ISBN: 698-4-18227-237-5
Downloads: 27909
Price: Free* [*Free Regsitration Required]
Uploader: Mausho

General Requirements for Delivery 3. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Recommended crosshead speed for cold-drawn? The outcome equals considerably longer tool life, increased productivity, better chip breaking, better dimensional tolerances, superior machined surface quality, reduced scrap losses, and consistent performance which translates to a reliable production schedule.

Work Item s – proposed revisions of this standard. This abstract is a brief summary of the referenced standard. BrinellB Hardness, max, HB Last previous edition approved in as F — Published information has shown no adverse effect for compositions containing up to 1.

LS / LVM Surgical Stainless Steel Bar – ASTM F

A number in parentheses indicates the year of last reapproval. The level of mechanical properties for material in conditions other than those included in Table 1 and Table 2, shall be speci?

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Under minimum limit not applicable for elements where only a minimum percentage is indicated. The secondary premium melting step imparts improved cleanliness. Materials and Manufacture 5. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.

F — 03 Standard Speci? C Asttm supplied as hot-rolled bar for forging applications. Approved June 10, Combining values from the two systems may result in non-conformance with the standard. C Cold-drawn wire may be ordered to tensile strengths up to psi MPa with lower elongation as determined by customer and supplier. Also listed are important residual elements.

  LAMBDIN INTRODUCTION TO SAHIDIC COPTIC PDF

Axtm of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. Mm Ksi MPa Up to 0. While most manufacturers quickly turn to material costs as a primary means of lowering their price, these short-term accommodations are not always sustainable. Hardness determination on cold-worked material shall be made on a product cross-section, midway between the center and surface, if cross-section size is adequate.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? Find out more by contacting us at Current edition approved June 10, Product analysis d138 shall be as speci?

Analysis for elements not listed in Table 3 is not required to certify compliance with asstm speci? Bar and wire shall be furnished, as specified, in the hot-worked, annealed, cold -worked, or extra hard condition. Billet shall also be ultrasonically tested prior to being hot rolled and should be free of internal defects. Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

Based upon this, metallurgical requirements include? On the other hand, types of finish available for fine wire products are cold-drawn, ground, and ground and polished. The SI units given in parentheses are for information only.

g138 A superscript epsilon e indicates an editorial change since the last revision or reapproval. It is not warranted or guaranteed. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Link to Active This link will always route to the current Active version of the standard.

  ISO 13936-2 PDF

316LS / 316LVM Surgical Stainless Steel Bar – ASTM F138

The percentage iron content by difference is not required to be reported. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

Due to the well characterized level of local biological response astn by this material, it has been used as a control material in Practice F Historical Version s – view previous versions of standard.

The values stated in each system qstm not be exact equivalents; therefore, each system shall be used independently of the other. However, long term clinical experience has shown an acceptable level of f1388 response can be expected, if the material is used in appropriate applications. Types of finish available for bar and wire products are cold-drawn, pickled, ground, and ground and polished.

The manufacturer shall not ship material that is outside the limits speci? Advanced ladle metallurgy allows for fine adjustments of the composition, amount, size, shape and distribution of the nonmetallic satm normally occurring within standard stainless steel.

Alternatively, a gage length corresponding to ISO may be used when agreed upon between supplier and purchaser. Originally approved in Acceptance criteria shall be agreed to between pruchaser and supplier. This specification covers the requirements for wrought 18chromiumnickel Quality Program Requirements